Group 28 Troubleshooting MID 128 PPID 337 Ash Level MID 128 PPID 387 Temperature Sensor, Catalytic Converter 39 Type of fault: FMI Description: Fault Condition: Possible Symptoms: Possible Cause: FMI 0 • Data valid but above normal operational range • Ash level too high • Need service • Short intervals between filter regenerations Type of fault: FMI Description: Fault Condition: Possible Symptoms: Possible Cause:
FMI 2 • Data erratic, intermittent or incorrect • Sensor is not rational • Poor driveability • Harness connected to incorrect sensor • Sensor failure FMI 4 • Voltage below normal or shorted low • Short to ground on the metering side of the circuit • Poor driveability • Faulty harness • Sensor failure FMI 5 • Current below normal or open circuit • Short to battery on the metering side of the circuit • Open in the metering side of the circuit • Open in the ground side of the circuit • Poor driveability • Faulty harness • Actuator failure FMI 10 • Abnormal rate of change • Sensor is stuck • Poor driveability • Sensor failure