D Group 28 Troubleshooting MID 130 PID 177 Oil Temperature, Transmission Note: FMI 0 has three levels of severity, low, medium and high. All times are reset when the key is switched off. 70 Type of fault: FMI Description: Fault Condition: Possible Symptoms: Possible Cause:
FMI 0 (Low) • Data valid but above normal operational range • The sensor signal is in normal range • Temperature is above 100 C (212 F) during 18000 s • Yellow lamp is sent • Symbol for high transmission oil temperature is lit • N/A FMI 0 (Medium) • Data valid but above normal operational range • The sensor signal is in normal range • Temperature is above 120 C (248 F) during 600 s • Yellow lamp is sent • Symbol for high transmission oil temperature is lit • N/A FMI 0 (High) • Data valid but above normal operational range • The sensor signal is in normal range • Temperature is above 140 C (284 F) during 30 s • Red lamp is sent • Symbol for high transmission oil temperature is lit • N/A FMI 4 • Voltage below normal or shorted low • The sensor signal is below normal range • Yellow lamp is sent • N/A FMI 5 • Current below normal or open circuit • The sensor signal is above normal range • Yellow lamp is sent • N/A