Thermostat housing TCD 2013 2V W 38-01-02 Checking the thermostat (in the removed state) Standard tools: Thermometer W 38-01-01 Danger! Risk of injury! Hot water and hot thermostat. 6 Checking thermostat ●Remove thermostat. W 38-01-01 ●Measure beginning of stroke, dimension (a). ●Note measured value, dimension (a). © 44585-0 ●Heat up the thermostat in the water bath. ●Determine beginning of opening. In order to determine the exact beginning of opening, the temperature should be measured as close as possible to the ther - mostat. Do not touch the thermostat. The water should be continuously stirred for an even temperature distribution.
The temperature rise should not take place fas - ter than 1°C/min. Otherwise the beginning of opening will be delayed accordingly. 83 °C © 34680-2 © 02/2010 OBJ_DOKU-21798-001.fm 1/2