OPERATOR'S STATION 4. Rotate selector knob (2) to highlight Aftertreatment Device Regeneration Inhibited (6). 2 MNEC-01-006 5. Press selector knob (2) to display Aftertreatment Device Regeneration Inhibited screen (7). 6 6. Rotate selector knob (2) to highlight (8), and press selector knob (2) to display Aftertreatment Device Regeneration Inhibited screen (9). MNHG-01-170EN 7 7. Rotate selector knob (2) to highlight ON (10). Confirmation screen is added. 8 Press selector knob (2) to turn Aftertreatment Device Regeneration Inhibited ON. Press selector knob (2) again to turn Aftertreatment Device Regeneration Inhibited OFF.
MNHG-01-171EN When ON is selected, regeneration inhibited icon (11) will be displayed on the monitor. f NOTE: When the function is ON, the mark " " is displayed in 9 green. When the function is OFF, the mark " " is displayed in gray. 10 IMPORTANT: This procedure will inhibit both automatic and manual regeneration. When the machine is operated with the aftertreatment device regeneration inhibited, the aftertreatment device becomes clogged more quickly than expected. When the aftertreatment device regeneration request is displayed, move the machine to a safe place. Perform the manual regeneration following the specified procedure. Failure to do so may damage the aftertreatment device.
Refer to page 5-13 for the manual regeneration. 11 MNHG-01-172EN 1-58