Hitachi Construction Machinery — AUTO

OPERATOR'S STATION Fan Reverse Rotation Switch Fan reverse rotation switch (1) reverses the hydraulic driven fan. In case the radiator is clogged, rotate the hydraulic driven fan in reverse direction to blow out the clogged dust. It is recommended to carry out the fan reverse rotation regularly to prevent the cooling system from clogging. 1 OFF When fan reverse rotation switch (1) is set to OFF position, the fan turns in normal direction. AUTO 115MNEC-07-01 When fan reverse rotation switch (1) is set to AUTO position, the fan rotates in the normal direction for 10 minutes for the first time. Then, the fan automatically reverses rotation and again return to the normal direction.

(Normal rotation Reverse rotation Normal rotation ) After that it keeps normal rotation for 30 minutes. The reverse rotation time is 60 seconds (1 minute). (90 seconds (1.5 minutes) at low temperature) 1 ON OFF (Neutral) In case abnormal situation occurs such as engine coolant overheating or high refrigerant pressure of the air conditioner, the duration time of reverse rotation may be shortened to protect devices from damage. AUTO MNEC-01-019 f NOTE: After depressing the AUTO side of this switch, the fan auto-reversing function remains activated as the switch position is kept being depressed until it is manually returned to OFF or ON position. 1-106