Komatsu — CHECKING BRAKE SYSTEM OIL LEVEL

MAINTENANCE MAINTENANCE AFTER FIRST 50 HOURS OF OPERATION (ONLY FOR MACHINES IN WHICH SYNTHETIC BIODEGRADABLE OIL TYPE HEES IS USED) The following maintenance operation must be performed after the first 50 hours of operation, together with maintenance operations to be initiated “EVERY 50 HOURS”. HYDRAULIC OIL DRAIN FILTER CHANGE For further details on the various maintenance operations, See “MAINTENANCE EVERY 500 HOURS OF OPERATION” on page 3-41.

MAINTENANCE EVERY 50 HOURS OF OPERATION CHECKING RADIATOR FLUID LEVEL Perform this check with the machine parked on level ground and loader arm raised with the safety lock engaged Do not remove the radiator cap when the fluid is hot, since the fluid may be sprayed out of the radiator and cause burns. Loosen the cap slowly to release the pressure before removing it. The radiator cap can be reached after opening the engine hood. Remove the cap (1) and make sure that the fluid is very near the filling hole.

# If level of fluid in the radiator is low and the expansion tank is filled with coolant, check cap tightness and make sure that there are no air leaks from the coupling that connects the radiator and expansion tank. If problem persists, contact your Komatsu Dealer. CHECKING BRAKE SYSTEM OIL LEVEL The brake reservoir ( 1 ) can be reached after opening the engine hood. This is a visual check and the reservoir must be topped off with the prescribed fluid until reaching the MAX. mark (See “FUEL, COOLANT, AND LUBRICANTS” on page 3-7). # Use new oil only.

# If constant and considerable leakages are observed, it is advisable to contact your Komatsu Dealer to have the system checked and necessary repairs made. 3-32 WB140-2N, WB150-2N