hitachi — REMOVE AND INSTALL PUMP DEVICE

UPPERSTRUCTURE / Pump Device 12. Install hose (31) to air cleaner (27). Tighten band (29) with nut (30). : 11 mm 13. Install the terminals (2 used) of contamination sensor (28). 14. Install bracket (17) with bolts (19) (4 used). W1J1-02-04-042 17 18 19 : 19 mm 8 : 90 N m (9.2 kgf m, 66 lbf ft) 15. Install bracket (22) with bolts (18) (3 used). 21 22 : 90 N m (9.2 kgf m, 66 lbf ft) 16. Install bracket (8) to bracket (22) with bolts (21) (4 used). : 19 mm : 90 N m (9.2 kgf m, 66 lbf ft) : 19 mm CAUTION: Cover (15) weight: 32 kg (70 lb) 17. Install covers (11, 15) with bolts (16) (11 used). W1J1-02-04-040 : 19 mm : 90 N m (9.2 kgf m, 66 lbf ft) NOTE:

Cover (11) and the rain cover are attached to cover (15). W1J1-02-04-038 W2-4-11 27 28 Terminal 29 30 31 27 nal Termi nal 15 Rain C 1 over 1 6