hitachi — REMOVE AND INSTALL FAN MOTOR

UPPERSTRUCTURE / Fan Motor 6. Remove refrigerant in the air conditioner. Remove hoses (14) (2 used) from condenser (10). Cap the adapter in condenser and hose (14). As for the procedures to remove refrigerant, refer to the operator’s manual. Radiator Assembly : 19 mm 7. Remove the bands (2 used) from hoses (12) (2 used). Remove hoses (12) (2 used) from fuel cooler (11). Drain fuel in the hoses between engine and fuel cooler (11) and between fuel cooler (11) and fuel tank. Cap fuel cooler (11) and hose (12). 8. Remove connector (15) from fresh air temperature sensor (16). W1J1-02-13-008 10 14 11 W1J1-02-13-013 16 15 W1J1-02-13-014 W2-13-2 13