UPPERSTRUCTURE / Engine IMPORTANT: Before removing nut (111) from the terminal in starter motor (112), remove the grounding wire in battery. If the work is continued with the grounding wire connected, the circuit may be shorted. 32. Remove nuts (111) (2 used). Remove harness (114) from the terminal in starter motor (112). Remove nut (113). Remove the grounding wire from the bracket. : 17 mm, 22 mm 33. Remove bolts (115) (3 used). Remove clips (116) (3 used) from harness (118). Disconnect connectors (119 to 123). Disconnect connector (117) in the oil level switch. 114 Grounding Wire W1J1-02-14-009 115, 116 117 Engine : 17 mm 34. Remove bolts (125) (5 used).
Remove clips (126) (5 used) from harness (124). Disconnect connectors (127, 128, 129). 123 122 115, 116 121 120 119 115, 116 : 17 mm W1J1-02-14-007 118 W2-14-9 111 112 Bracket 124 125, 126 125, 126 127 125, 126 125, 126 125, 126 129 128 Pump W1J1-02-14-008 125, 126 Pump