DD Heavy Duty Platform Operators Manual NOTE: If a parked regeneration is being performed to check NOx conversion, the calculated ambient temperature in the ACM (AS053) must be above 0°C (32°F) or the test will fail. NOTE: If the HEST LAMP is FLASHING, a regeneration is in process and the system is coming up to temperature. 1. Keep engine at slow idle (cannot be in Fast Idle or PTO Mode). Put transmission in neutral (if equipped with an automatic transmission, cycle it into gear and then back to neutral). NOTICE: Air tank pressure must be high enough for the parking brake switch to hold in the OFF position. 2. Set park brake (cycle the park brake OFF then ON for CPC R21 or lower software).
3. Press and release clutch pedal once per ignition cycle (if configured). 4. Hold DPF Switch to the ON position for five seconds and then release (engine speed will increase and DPF lamp will go out). All information subject to change without notice. 99 DDC-SVC-MAN-0189 Copyright © 2022 DETROIT DIESEL CORPORATION