Perkins — To test and to inspect Operation 12-6

12 400 Series To test and to inspect Operation 12-6 Visually inspect for damage, renew the thermostat if the valve is open at ambient temperature. 1 Put the thermostat into the water. 2 Raise the temperature of the water gradually. 3 Record the valve opening temperature and the valve lift. Notes: The start to open temperature is stamped on the thermostat 3 to 5 minutes will be required before the valve starts to operate. H1107 96 Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: