Perkins — To clean the engine breather assembly

400 Series 9 Aspiration system 9 Breather system Closed circuit, naturally aspirated - to clean and to renew Operation 9-1 To clean the engine breather assembly The breather assembly should be renewed every 2000 hours. Caution: Ensure that the components of the breather assembly are fitted in their correct position (1 - 6). If they are incorrectly fitted, the engine may be damaged. 1 Release the four setscrews (2) and remove the breather cover (1), the spring (6) and the diaphragm assembly (4). Caution: It is important that the area around the vent hole (3) is clean. 2 Clean the breather cavity (5) in the rocker cover.

3 Clean the breather in clean diesel fuel 4 Fit the breather assembly into the cavity in the rocker cover, ensuring that the breather cover, diaphragm and spring are assembled correctly and that the vent hole (3) faces towards the flywheel. Tighten the four setscrews. Clean the breather only with a clean diesel fuel. If the breather is damaged or the diaphragm perforated, renew the breather. 1 2 3 6 4 5 H1089 Workshop Manual, TPD 1458E, issue 3 - Perkins Confidential: Green 73