. MAINTENANCE MAINTENANCE PROCEDURE CLEAN AND INSPECT RADIATOR FINS, OIL COOLER FINS, AFTERCOOLER FINS AND CONDENSER FINS WARNING again, as instructed in the step 8.) Steam or water may be used instead of compressed air. 6. Check the rubber hose. Replace with a new one if the hose is found to have cracks or to be hardened by aging. In addition, check the hose clamps for looseness. 4 - 62 If compressed air , high-pressur e water , or steam hits your body d irectly or dirt is sent flying by the com pressed air, high-pressure wate r, or steam, t here is dange r of personal inju ry. Always wear protective glasses, dust mask, and o ther protective equipment.
NOTICE Whe n using com pressed air for cleaning, blow it keeping some di stance to avoid damaging the fins. Da mage on the fins can cause wate r leakage an d overheating. In a dusty job si te, check the fin s every day, regardless of the mainte 1. Open the e 2. Loosen scr ew (1) and p ull up 3. 4. Remove 6 bolts (3), th en move brack et (4) to the side and 5. I l make a gap nspect the after-cooler eaves, etc between ra front and rea fins (7) and . Blow them diator fins (5) a r of radiator fin condenser fin away with c nd oil cooler fi s (5), oil coole s (8) for dirt, ompressed air ns (6). r fins (6), dust, dry , if any.