Komatsu — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. Stop the machine on level ground when cleaning or changing the coolant. When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mixing rate table given below. It is actually better to estimate a temperature about 10°C (50°F) lower when deciding the mixing rate. Mixing rate of water and antifreeze Min. atmospheric temperature Amount of antifreeze Amount of water l We recommend use of an antifreeze density gauge to control the mixing proportions.

l Use city water for the cooling water. If river water, well water or other such used, contact your Komatsu distributor. water supply must be 3-23