Unit : kgf / cm 2 7-17 16)MAIN PUMP DELIVERY PRESSURE (1) Preparation ① Keep the hydraulic oil temperature at 50±5˚C. (2) Measurement ① Select the following switch positions. ·Power mode switch : P mode ② Measure the main pump delivery pressure by the monitoring menu of the cluster. (3) Evaluation The average measured pressure should m eet the following specifications. Model Engine speed Standard Allowable limits Remarks R505LVS High ilde 40± 2 -