15. LONG-TERM STORAGE 15.1 BEFORE STORAGE When putting the machine in storage for more than one month, do as follows. After every part is washed and dried, the machine shall be housed in a dry building. Never leave it outdoors. In case it is indispensable to leave it outdoors, park the machine on the flat ground and cover it with canvas etc. Completely fill the fuel tank, lubricate and change the oil before storage. Apply a thin coat of grease to metal surface of the hydraulic piston rods and the idler adjusting rods. Disconnect the negative terminals of the battery and cover it, or remove it from the machine and store it separately.
If the ambient temperature is expected to drop below OX, always add antifreeze to the cooling water. Place all control levers at the neutral position, operate the safety lever and parking lever to the LOCK position, then move the fuel control dial to the low idling position. 15.2 DURING STORAGE &L WARNING If it is unavoidably necessary to carry out the rustpreventive operation while the machine is indoors, open the doors and windows to improve ventilation and prevent gas poisoning. l Operate the engine and move the machine for a short distance once a month so that a new film of oil will be coated over movable parts and component surfaces. At the same time, also charge the battery.
l Before operating the work equipment, wipe off the grease on the hydraulic piston rod. 15.3 AFTER STORAGE NOTICE If the machine is stored without carrying out the monthly rust prevention operation, request your Komatsu distributor for service. Carry out the following procedure when taking the machine out of long-term storage. l Wipe off the grease from the hydraulic cylinder rods. l Add oil and grease to all places. 2-76