Komatsu — 24.5 EVERY 500 HOURS SERVICE

24. SERVICE PROCEDURE 8. Clean the bypass filter holder. Fill a new bypass filter cartridge @ with clean engine oil. Coat the packing surface and thread of a new filter cartridge with engine oil (or coat it thinly with grease), then install it to the filter holder. 9. When installing, tighten until the packing surface contacts the seal surface of the filter holder, then tighten it up 3/4 to 1 of a turn. 10. After replacing the filter cartridge, refill engine oil from oil filler @ up to the range between the H and L marks on the dipstick. For details of the oil to use, see “20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE”.

When adding oil, be careful not to get oil on the alternator. 11. Run the engine at idling for a short time, then stop the engine, and check that the oil level is between the H and L marks on the dipstick. For details, see “24.3 CHECK BEFORE STARTING”. NOTICE Even if the machine has not been operated for 500 hours, the oil and filter cartridge must be replaced when the machine has been operated for 6 months. In the same way, even if the machine has not been operated for 6 months, the oil and filter cartridge must be replaced when the machine has been operated for 500 hours. Do not loosen drain valve @ too far, otherwise, the stopper pin inside the valve may be deformed.

24.4.5 CHECK FAN BELT An auto tensioner is installed to maintain a constant belt tension regardless of any elongation of the V-belt, so there is no need to carry out any adjustment until the belt is replaced. Check the V-belt, and replace it with a new part if any of the following abnormality are found. CHECK l Is the V-belt in contact with the bottom of the pulley groove? l Is the V-belt worn and below the outside circumference of the pulley? l Is the V-belt cracked or peeled? 3-48