30 Fuel System 20-4 ROOSA MASTER Fuel Injection Nozzles Model 2120 Tractor TM-4252 (Dec-70) TESTING INJECTION NOZZLE WITH NOZZLE TESTER Connect the injection nozzle to the tester as shown in fig. 6 so that the axis of the injection nozzle forms an angle of approx. 30° to the vertical, and the spray of fuel is directed downwards and all of it is collected in the container underneath. Make sure that all connections are leakproof to avoid false results when testing. NOTES: Testing the performance of a nozzle while the engine is running (see above) is just a rough test. To obtain a true check of nozzle performance , use a nozzle tester, such as - Robert Bosch, part. No. EFEP 60 A (see fig.
6) (or from Messrs. Bacharach, see part No. 65-030 D). To connect a nozzle to the BOSCH tester, use special tool (fuel pressure line) No. 19-58-90.577. For connection to the BACHARACH nozzle tester use special tool (connecting piece) No. 16492. Close the gauge shut-off valve and flush (bleed) the nozzle by operating test pump rapidly. Thus, the nozzle valve, too, will seat. SPRAY PATTERN TEST Use only carefully filtered Diesel fuel for testing the injection nozzles, since dirty fuel will severely damage the precision parts of a nozzle. Close gauge shut-off valve and operate the pump lever at 60 strokes per minute.
If the injection nozzle is working properly, the fuel should issue through all nozzle orifices in a fine, evenly shaped spray cone. This spray cone is inclined from the centerline of the nozzle body, but should be evenly distributed. For a better check, place a piece of paper or cardboard at a suitable distance below the nozzle and check the appearance of the damp cir¬ cular spots made by the fuel. Deviations from the regular spray pattern or angle may be due to the complete or partial clogging of a nozzle orifice. In this case the fuel issues in a jet rather than in a fine spray. CAUTION: The nozzle tip must always point away from the operator.
The fuel issuing from an orifice can penetrate clothes and skin and thus cause severe infection. It is therefore advisable to direct the jet of atomised fuel into a transparent con¬ tainer (see fig. 6). CHATTER TEST Make sure nozzle orifices are free. When working pump of injection nozzle tester at 60 strokes per minute (gauge shuLoff valve closed), a definite characteristic "chatter" should be heard. If this is not the case, the nozzle needle may be bent, or tight in its guide because of the laquer deposits which have accumulated. This can be corrected only by disassembling the nozzle. TESTING OPENING PRESSURE NOTE:
Absolute opening pressure is less important than equal opening pressure of all nozzles. Max. permissible variation see Specifications. Fig. 6 ROOSA MASTER Injection Nozzle Con¬ nected to BOSCH Tester Printed in Germany