John Deere 2120 Tractor — tm4252

Model 2120 Tractor TM-4252 (Dec-70) Fuel System 30 ROOSA MASTER Fuel Injection Nozzles 20-9 CAUTION: Too much lapping will cause an undesirable extension of the effective sealing surface between nozzle and body. This prevents the normal "chattering" and results in uneven spraying. Screw lift adjusting screw 12 into spring pressure adjusting screw 14 until slotted end of screw is roughly flush with hex. head of spring pressure adjusting screw. Screw lock nut 13 completely onto spring pressure adjusting screw 14. Hold both screws in such a way that the pointed end of the lift adjusting screw faces upward and insert in succession, as per fig.

1, ball washer 11, upper spring seat 10, pressure spring 9 and lower spring seat 10. Tilt nozzle body, as shown in fig. 15 (CAUTION: Do not allow the needle to slide out), and screw the adjusting screw 14, together with the internal parts completely into the body (normally 10 complete turns). Use care not to dislodge the spring seats and spring. VALVE ADJUSTING MECHANISM Make sure the stroke adjusting screw 12 is not bent. A bent or otherwise damaged adjusting screw must be replaced with a new part. Also check that spring pressure adjusting screw 14 is still usable. Replace if necessary.

Check if the remaining components - both spring seats 10, pressure spring 9, ball washer 11, lock nut 13 and clamp 15 - are still usable; if necessary, replace them. ADJUSTMENT ASSEMBLY PREPARATIONS STEP 1 Clamp the injection nozzle in a vise, using tool No. 16475 provided with the nozzle tool kit and loosen lock nut 13 on the adjusting screw (see fig. 7). Slip locating clamp 15 over nozzle body with bent ends down. Rinse the needle in well-filtered Diesel fuel and insert it into the body. Loosen lift adjusting screw 12 by at least two turns (counterclockwise). CAUTION: Use greatest care when handling needle. Connect the injection nozzle to the tester (as shown in fig.

6) so that its centerline forms an angle of approx. 30° with the vertical. Make sure that the connections do no leak. Close gauge shut-off valve and operate the pump several times quickly, thus flushing the nozzle thoroughly (bleeding). This will seat the needle. CAUTION: The nozzle tip must always face away from the person operating the tester. The fuel issuing from an orifice can penetrate clothes and skin, causing serious infection. It is, therefore, advisable to direct the spray into a transparent container (see fig. 6). 3я0175 ADJUSTING OPENING PRESSURE Fig. 15 Assembly of Injection Nozzle NOTE:

When setting nozzle opening pressure, it is desirable to adjust opening pressure toward the high rather than the low limit. Repeat measuring process to obtain proper result. Printed in Germany