40 Electrical System 10-4 Components and Wiring Diagrams Model 2120 Tractor TM-4252 (Dec-70) FSS NOTE: For detailed explanation of alter¬ nator repair operations see " Fundamentals of Service— Electrical Systems" manual as well as " Repair Instructions" of manu¬ facturer. Necessary specifications are indicated at the end of this group. IMPORTANT: If the generator fails to function properly and is removed for inspection, the regulator should also be removed and tested. When installing a new or reconditioned generator, have the regulator checked, too. Failing to do so may cause damage to the new or reconditioned generator. When installing the alternator, reverse removal procedure. NOTE:

For detailed explanation of generator repair operations see "Funda¬ mentals of Service Electrical Systems" manual. Necessary specifications are indicated at the end of this group. For checking and adjusting fan belt tension see section 20, group 35. GENERATOR When installing the generator, reverse removal procedure. Make sure that wires and cables are not mixed up (see Wiring Diagrams). GENERAL INFORMATION For checking and adjusting fan belt tension see section 20, group 35. REGULATOR GENERAL INFORMATION Tractors equipped with Alternator A single unit, 2-terminal regulator is used for regulating the alternator voltage. The 2-terminal regulator limits the alternator voltage to approx.

14 Volts. No current regulation is required as the alternator current curve rises to its maximum value and then flattens out at maximum alternator speed. Fig. 4 Generator and Regulator, Installed 1 Generator 2 Regulator The regulator is located in the tractor dashboard. To remove the regulator, detach right-hand side panel of cowl. The Bosch 12-volt generator is V-belt driven by the crankshaft. The armature is supported by two pre- lubricated bearings. The generator is completely enclosed. The carbon brushes can be reached only after removing the rear bearing cover. CAUTION: Disconnect cable plug only with the engine shut-off. F0S 1 NOTE:

For a detailed explanation of alter¬ nator-regulator design and operation see "Fundamentals of Service— Electrical Systems" manual. NOTE: For a detailed explanation of generator design and operation see "Funda¬ mentals of Service— Electrical Systems" manual. F0S Tractors equipped with Generator REPAIR The regulator is rubber-mounted above the generator (see fig. 4). Disconnect generator wires. Remove cap screws and spacer. Take out generator. IMPORTANT: Do not replace the regulator without having the generator carefully checked by a specialist. Always have regulator and generator inspected together; both parts rely on and influence each other. Printed in Germany