40 Electrical System 10-16 Components and Wiring Diagrams Model 2120 Tractor TM-4252 (Dec-70) Quick Check: Bridge both switch terminals with a piece of wire to close the circuit. If switch is faulty, both stop lights of the tractor and of the trailer (if hitched), should light up. If the lights fail to light up, the fault must be traced elsewhere. ground connection. The trouble may also be due to weak spring contacts exerting insufficient pressure on light bulbs. Re-bend contacts, if necessary. Corroded contacts in bulb sockets or on bulbs can also cause lighting trouble. Clean connections.
START SAFETY SWITCH If the starter does not work although the key is pressed in and the range shift lever is in neutral or park position, check the start safety switch by installing a new switch and check circuit. Ensure that the switch is set correctly (see "Adjustment"). ADJUSTMENT START SAFETY SWITCH Adjust start safety switch by installing as many shims between rockshaft housing and switch as needed to make contact on starter when the range shift lever is in neutral position, but not if it is in range I or II. NOTE: The start safety switch can be checked in the same manner as the stop light switch (see above). CAUTION:
Do not overtighten switch when installing it in the rockshaft housing. For maximum torque see Specifications. HEAD LIGHTS, PARK AND TURN SIGNAL LIGHTS, STOP AND TURN SIGNAL LIGHTS AND TAIL LIGHTS HEAD LIGHTS Apart from bulbs blowing, faults on these lights are normally caused by bad connections. This applies especially to ground connections. For adjusting the head lights, use a commercial head light testing device. Test each head light individually. Make the required corrections by turning the head light in its pivoting mounting. Check ground connections as follows: Connect a length of wire to a bare metal area of the light housing and to bare spot on the tractor frame.
Bulb should light brighter if cause was poor SPECIFICATIONS STARTER ELECTRICAL TEST NOTE: The test period should be as short as possible; batteries installed in the test stand should be well charged and function properly ( battery capacity: 135 Ah). Test starter at room temperature (approx. 20°C = 68° F). On a defective starter the electrical test values differ considerably from specifications given on the next page! If in doubt , check field and armature windings for breaks, ground or winding short-circuits. Printed in Germany