Armature end play ... 0.004 to 0.012 in. Out-of-roundness of rotor, maximum ............... 0.002 in. 0.05 mm 40 Electrical System 10-20 Components and Wiring Diagrams Model 2120 Tractor TM-4252 (Dec-70) Isolation gap to alternator housing, minimum .......... 0.12 in. 3 mm TESTING ALTERNATOR SPECIFICATIONS (CONT.) GENERATOR ELECTRICAL TEST NOTES: When testing generator and regulator, check for proper connection and polarity of regulator. When testing generator without regulator , no-load speed at rated voltage and output speed (cold and hot) can be measured. To do so, first connect terminal " DF " directly to terminal " D- " (thus only regulator failure can be eliminated when testing).
Make sure output speed is not exceeded considerably at generator voltage as this would damage the exciting coil. When putting the generator to an endurance test, it is recommended to use the regulator, too. This will avoid a voltage surge. Do not test the generator in an endurance test at double output speed without using the regulator. When generator failure is evident, always check the regulator. 1. Operate generator as a motor for a short time. To do this, separate generator from drive motor of test bench. Connect battery directly to terminal "D+". The generator should now run as a motor in its normal direction of rotation. 2.
No-load speed at rated voltage (see chart) Connect voltmeter to terminal "D+" and ground (using an insulated ground wire) to "D-". Increase speed slowly. With no-load speed at rated voltage, the generator voltage should be reached ("cold"). Speed when testing output "cold"; Speed when testing output "warm"; Ambient temperature should be Housing temperature should be approx. 68° F (20° C). approx. 140°F (60°C). 3. Adjusting load Adjusting load always corresponds to 2/3 of maximum amperage. When testing output, increase ohm value of resistor installed in test bench until load amperage is obtained (see chart). Record relative speed and compare to actual speed.
No-load speed at rated voltage Speed when testi cold ng output hot Load amperage Resistance 1250 to 1450 rpm 1700 to 1900 rpm 1850 to 2000 rpm 7.5 Amperes 3.5 Ohms + 10 % Out-of-roundness of stack of armature plates, max .......... 0.002 in. CHECKING GENERATOR SPECIFICATIONS Undercutting insulation after re-turning commutator by approx. (then finish-turn) .......... 0.02 to 0.03 in. Minimum dia. of commutator (when re-turning: CAUTION! Centerings of armature shaft are out of center) 1.22 in. 31 mm Brush pressure (check by means of a spring scale) ....... 1.0 to 1.3 lbs. Commutator out-of-roundness, max 0.0012 in.
0.03 mm 0.05 mm 0.5 to 0.8 mm 0.45 to 0.6 kg TORQUES FOR HARDWARE 0.1 to 0.3 mm Start safety switch inrockshaft housing, max 35 ft.lbs. 4.8 mkg Pulley to generator 29 ft.lbs. 4 mkg Printed in Germany