Model 2120 Tractor TM-4252 (Dec -70) Power Train 50 HIGH-LOW Shift Unit 10-5 A broken transmission filter relief valve spring could also cause the low flow in the system. CHECKING OPERATION OF INDEPENDENT PTO (if equipped) However, if rockshaft or remote cylinder operate properly, all the components in the main hydraulic pump charge circuit can be considered in good condition and the problem is in the HIGH-LOW circuit. On tractors equipped with independent PTO, con¬ nect a manometer No. 19.58-90.260 of special tool No. 19.58-90-260 to pressure oil channel of PTO clutch and one to pressure oil channel of PTO brake (see group 35). Connect a further mano¬ meter No.
19.58-90.268 to pressure regulating valve (see fig. 3). Check for a broken pressure regulating valve spring or a sticking pressure regulating valve. Start engine. Fully engage and disengage PTO by means of control lever. The manometer connected to pressure channel of pressure regulating valve and one of the two manometers connected to PTO pressure oil channels (depending on position of PTO control lever) should show a pressure of 140-160 psi (9.8-11.2 kg/cm2). CHECKING OPERATION OF HIGH-LOW SHIFT UNIT Operate tractor in both HIGH and LOW ranges, carefully observing both operations. Use the brakes to simulate a load condition on the tractor.
Low oil pressure in the HIGH-LOW control valve assembly will be indicated by equal disk pack slip¬ page in both ranges. If operation is normal in one range and not in the other, a mechanical failure in the HIGH- LOW shift unit is probably the cause. When this pressure is not reached, slowly move PTO control lever until both manometers con¬ nected to PTO pressure oil channels show no pres¬ sure. Now oil flow to PTO clutch and brake is interrupted and the pressure regulating valve isolated. The operating pressure at pressure regu¬ lating valve should now read 140-160 psi (9.8-11.2 kg/cm2). Always check operating pressure before disas¬ sembling the HIGH-LOW shift unit. NOTE:
Speed of shifting on HIGH-LOW unit is not adjustable. However, the unit should shift instantly when the control lever is moved. The correct pres¬ sure adjustment assures oil for fast engagement of HIGH-LOW disk packs. If, with the PTO engaged or disengaged, the operating pressure is too low but not with isolated pressure regulating valve, a leak in the PTO oil system will be the cause (see group 35). If operating pressure is too low both with engaged or disengaged PTO and with isolated pressure regu¬ lating valve, the fault will not be found at the inde¬ pendent PTO. Printed in Germany