Model 2120 Tractor TM-4252 (Dec-70) Hydraulic System 70 General Information, Diagnosing Malfunctions, Pressure Tests 5-9 gauge reading when actuated hydraulic component starts to operate normally. This value indicates flow control valve adjustment. For proper flow control valve adjusting pressure see Specifications. If adjusting pressure is not correct, add or remove shims between valve spring and throttle (see group 10 of this section). One shim will change pressure by 35 to 40 psi (2.5 to 2.8 kg/cm2). To adjust the flow control valve, disconnect pressure line of hydraulic pump at adapter. Remove adapter from valve housing (see group 10).
Pull spool out of valve housing bore and install proper number of shims between throttle plate and spring. Fig. 4 Pressure Gauge Connected to Hydraulic Pump Adjust pressure control valve of hydraulic pump so that correct system stand-by pressure is obtained. 1 Pressure gauge No. 19. 58-90. 269 of special tool No. 19.58-90.260 2 Pressure hose assembly of special tool No. 19.58-90.260 3 Elbow No. 19.58-90.270 of special tool No. 19,58-90.260 4 Adapter No. 19.58-90.271 of special tool No. 19.58-90.260 TESTING LIFT CYCLES ROCKSHAFT Adjust pump pressure regulating valve to 1500 psi (105 kg/cm*). Run engine at 2100 rpm.
Actuate control lever of one of the hydraulic components which do not have priority in oil supply (rockshaft or selective control valve); it should not operate. If component operates, this indicates a malfunction of the flow control valve (contaminated valve or broken valve spring). Deter¬ mine cause of trouble and remove (see group 10 of this section) before continuing the test. Lift arms should be in their lowest position. Move rockshaft control lever backward until lift arms are in top position. Rising of lift arms in top position should require a specified period (see Specifications). REMOTE CYLINDER Carry out any of the following two operations:
Run engine at 2100 rpm and actuate selective control lever to extend remote cylinder piston. Remote cylinder should be completely extended in specified period (see Specifications). If extending or retracting cylinder requires more or less time, turn out adjusting screws to selective control valve to reduce lift cycle. Turn in screws to extend lift cycle (see group 35). 1. Move rockshaft control lever fully forward so that lift arms are completely lowered. Then move control lever backward until lift arms have completely risen. 2. Completely retract remote cylinder. Then move selective control lever in "fast extend" position.
Turn adjusting screw of pump pressure regulating valve so as to increase system pressure. Record Printed in Germany