hyundai R510LC-7 — 2. MAIN CIRCUIT

3. DRAIN CIRCUIT Travel motor Swing motor Turning joint From return line Main pump dr2 ~ dr8 Hydraulic oil tank Spin filter dr1 Check valve 1.5 kgf/cm 2 29073CI02 Besides internal leaks from the motors and main pump, the oil for lubrication circulates. These oil have to be fed to the hydraulic tank passing through spin filter and full flow filter in the hydraulic tank. When the drain oil pressure exceed 1.5 kgf/cm 2 (21 psi ), the oil returns to the hydraulic tank directly. 1) TRAVEL MOTOR DRAIN CIRCUIT Oil leaking from the right and left travel motors comes out of the drain ports provided in the respective motor casing and join with each other.

These oils pass through the turning joint and return to the hydraulic tank after being filtered by full flow filter in the hydranlic tank. 2) SWING MOTOR DRAIN CIRCUIT Oil leaking from the swing motor come out and return to the hydraulic tank passing through a spin filter. 3) MAIN PUMP DRAIN CIRCUIT Oil leaking from main pump come out and return to the hydraulic tank passing through spin filter. 3-4