GROUP 5 COMBINED OPERATION 1. OUTLINE 45073HC17 The oil from the front and rear pump flows through the neutral oil passage, bypass oil passage and confluence oil passage in the main control valve. Then the oil goes to each actuator and operates them. Check valves and orifices are located on these oil passage in the main control valve. These control the oil from the main pumps so as to correspond to the operation of each actuator and smooth the combined operation. STRAIGHT TRAVEL SPOOL This straight travel spool is provided in the main control valve. If any actuator is operated when traveling, the straight travel spool is pushed to the left by the pilot oil pressure(PP) from the pilot pump.
Consequently, the left and right travel oil supply passage are connected, and equivalent amount of oil flows into the left and right travel motors. This keeps the straight travel. 3-23