3. EPPR VALVE CHECK PROCEDURE Spec : 200~450 mA 1) CHECK ELECTRIC VALUE AT EPPR VALVE (1) Start engine. Multimeter CN-75 (2) Set S-mode and cancel auto decel mode. (3) Position the accel dial at 10. (4) 50 rpm , disconnect one wire harness from EPPR valve. If tachometer show approx 1650 EPPR valve (5) Install multimeter as figure. (6) Check electric current at bucket circuit relief position. 2507A5MS08 2) CHECK PRESSURE AT EPPR VALVE Spec : 2~25 kgf/cm 2 (30~350 psi ) (1) Remove plug and connect pressure gauge as figure. Gauge capacity : 0 to 40-50 kgf/cm 2 CN-75 Supply line, pilot pressure Pressure adjusting screw locknut (0 to 580-725 psi ) (2) Start engine.
(3) Set S-mode and cancel auto decel mode. (4) Position the accel dial at 10. EPPR valve (5) If tachometer show approx 1650 50 rpm , check pressure at relief position of bucket circuit by operating bucket control lever. (6) If pressure is not correct, adjust it. (7) After adjust, test the machine. 2507A5MS09 5-24