2) CLUSTER CHECK PROCEDURE (1) Start key : ON Check monitor initial 5 seconds a. b. All lamps light up. Buzzer sound. Check monitor after 5 seconds : Indicate cluster version and machine condition a. b. c. d. e. f. Cluster program version : for 5 seconds. Tachometer : 0 rpm Fuel gauge : All light up below appropriate level Hydraulic temperature : All light up below appropriate level Engine coolant temperature gauge : All light up below appropriate level Warning lamp During start key ON the engine oil pressure lamp and battery charging lamp go on, but it is not abnormal. When engine coolant temperature below 30 1.00 Indicates program version 1.00 C, the warming up lamp lights up.
Indicating lamp state a. b. c. d. e. Work mode selection : General work Power mode selection : S mode User mode selection : No LED ON Auto decel LED : ON Travel speed pilot lamp : Low(Turttle) (2) Start of engine Check machine condition a. b. Tachometer indicates at present rpm Gauge and warning lamp : Indicate at present condition. When normal condition : All warning lamp OFF Work mode selection : General work Power mode selection : S mode User mode selection : No LED ON Auto decel LED : ON Travel speed pilot lamp : Low(Turttle) c. d. e. f. g. When warming up operation a. b. Warming up lamp : ON 10 seconds after engine started, engine speed increases to 1000rpm(Auto decel LED :
ON) Others same as above When abnormal condition a. b. The lamp lights up and the buzzer sounds. If BUZZER STOP switch is pressed, buzzer sound is canceled but the lamp light up until normal condition. 5-26