6. MALFUNCTION OF POWER MAX Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE Wiring diagram CN-50 POWER MAX SOLENOID 3 MCU CN-88 2 2 1 FUSE CN-51 CN-4 NO.25 POWER MAX SWITCH 2 CS-29 1 51076MS03 6-48 YES Check resistance between CN-88 (1) - (2) Resistance YES between CN-51 SPEC: 15-30 (2)-GND normal? See TEST 8 NO SPEC : Power max Is voltage between button pressed ON : 0 CN-88(2) -GND Power max button released OFF : normal? SPEC KEY ON : 24 1V KEY OFF : 0V See TEST 8 NO Cause Remedy Defective power max.
solenoid valve Short circuit or poor connection between CN-51(2) - CS-29 and CN-50 (3) -CN-88(1) Short circuit or poor connection between CN-88(2)- battery relay(+) Repair or replace Repair or replace Repair or replace 1 2