hyundai R510LC-7 — 4. MECHATRONICS SYSTEM

7. MALFUNCTION OF PUMP 1 PRESSURE SENSOR 7. MALFUNCTION OF PUMP 1 PRESSURE SENSOR Before carrying out below procedure, check all the related connectors are properly inserted. 1) 1) INSPECTION PROCEDURE INSPECTION PROCEDURE Wiring diagram Wiring diagram CN-51 7 1 CD-42 A SUPPLY 4 B SIG 8 3 C RETURN 10 PUMP 1 PRESSURE SENSOR CN-1 MCU 51076MS04 6-50 YES YES Check voltage YES between CN-1(4)-GND Check voltage SPEC : between CN-51 NO Check voltage Actuator operating: 1~5V (10) - GND YES between SPEC : CD-42(A)-(C) Actuator operating: 1~5V See TEST 9 SPEC : Key ON : 24±2V Check voltage NO between NO CN-1(1)-(3) SPEC : Key ON :

24±2V NO Cause Remedy Defective MCU Short circuit or poor connection between CN-51- (10)-CN-1(4) Detective P1 pressure sensor Short circuit or poor connection between CN-1(4)- CD-42(B) Short circuit or poor connection between CD-42(A)-CN-1(1) or CD-42(C)-CN- 1(3) Short circuit or poor connection between CN-1(1)- CN-51(7) or CN-1 (3) - CN-51(8) Replace Replace or repair Replace or repair Replace or repair Replace or repair Replace or repair