hyundai R510LC-7 — 4. MECHATRONICS SYSTEM

9. MALFUNCTION OF PUMP 3 PRESSURE SENSOR 9. MALFUNCTION OF PUMP 3 PRESSURE SENSOR Before carrying out below procedure, check all the related connectors are properly inserted. 1) 1) INSPECTION PROCEDURE INSPECTION PROCEDURE Wiring diagram Wiring diagram CN-51 CD-44 7 1 A SUPPLY 6 B SIG 8 PUMP 3 PRESSURE SENSOR CN-1 3 C RETURN 12 MCU 51076MS08 6-54 YES YES Check voltage YES between CN-1(6)-GND Check voltage SPEC : between CN-51 NO Check voltage Actuator operating: 1~5V (12) - GND YES between SPEC : CD-44(A)-(C) Actuator operating: 1~5V See TEST 11 SPEC : Key ON : 24±2V Check voltage NO between NO CN-1(1)-(3) SPEC : Key ON :

24±2V NO Cause Remedy Defective MCU Short circuit or poor connection between CN-51- (12)-CN-1(6) Detective P3 pressure sensor Short circuit or poor connection between CN-1(6)- CD-44(B) Short circuit or poor connection between CD-44(A)-CN-1(1) or CD-44(C)-CN- 1(3) Short circuit or poor connection between CN-1(1)- CN-51(7) or CN-1 (3) - CN-51(8) Replace Replace or repair Replace or repair Replace or repair Replace or repair Replace or repair