hyundai R510LC-7 — 4. MECHATRONICS SYSTEM

10. MALFUNCTION OF NEGATIVE 1 PRESSURE SENSOR 10. MALFUNCTION OF NEGATIVE 1 PRESSURE SENSOR Before carrying out below procedure, check all the related connectors are properly inserted. 1) 1) INSPECTION PROCEDURE INSPECTION PROCEDURE Wiring diagram Wiring diagram CN-51 CD-70 7 1 A SUPPLY 8 2 3 B C SIG RETURN NEGATIVE 1 PRESSURE SENSOR CN-1 MCU 35 51076MS12 6-56 YES Check voltage YES between CN-51 (35) - GND SPEC : Actuator operating: 1~5V Check voltage See TEST 12 between CD-70 NO (A)-(C) SPEC : Key ON :

24±2V NO Cause Remedy Defective MCU Detective N1 pressure sensor Short circuit or poor connection between CN-52 (37)-CD-70 (B) Short circuit or poor connection between CD-70 (A)-CN-51(4) or CD-70(C)- CN-51 (5) Replace Replace or repair Replace or repair Replace or repair