Low tilting angle(low flow) command preferential function As mentioned above, flow control and horsepower control tilting angle commands are transmitted to the feedback lever and spool via the large-hole sections(C & F) of levers 1 and 2. However, since sections C and F have the pins( 8), only the lever lessening the tilting angle contacts the pin(897) ; the hole( 4) protruding from the large hole( 8) in the lever of a larger tilting angle command is freed without contacting the pin(897). Such a mechanical selection method permits preference of the lower tilting angle command of the flow control and horsepower control.
Adjustment of input horsepower Since the regulator is of total cumulative horsepower type, adjust the adjusting screws of both the front and rear pumps, when changing the horsepower set values. The pressure change values by adjustment are based on two pumps pressurized at the same time, and the values will be doubled when only one pump is loaded. a. Adjustment of outer spring Adjust it by loosening the hexagon nut(630) and by tightening(or loosening) the adjusting screw C(628). Tightening the screw shifts the control chart to the right and increases the input horse- power as shown in the figure.
Since turning the adjusting screw C by N turns changes the setting of the inner spring(626), return the adjusting screw CI(925) by N A turns at first.(A=1.54) Adjusting values are shown in table. 2-16 (210-7) Delivery flow, Q Delivery pressure, (P1+P2) 2-17 625 626 630 628 801 925 Speed (min -1) Adjustment of outer spring Tightening amount of adjusting screw(C) (628) (Turn) Compens- ating control starting pressure change amount (kgf/cm2) Input torque change amount (kgf m) 1900 +1/4 +17.85 +9.7