hyundai R510LC-7 — 2. MAIN CONTROL VALVE

2) SWING COMBINED OPERATION When swing and boom up functions are operated, the poppet(S2-1) is seated by pressure of port pc6 and the poppet(S2-3) only opened and the supply pressure of the parallel passage(L3) is rises by orifice(S2-4). As a result, boom and swing simultaneous operation is ensured even if lower load of swing section. 45071MC15 2-41