hyundai R510LC-7 — 2. MAIN CONTROL VALVE

3) LOW PRESSURE RELIEF VALVE (1) When pump does not operational 45071MC19 (2) When spool neutral The neutral passage(HP) oil flows into the low pressure passage(LP) via signal orifice(S). The signal port 4Ps(5Ps) pressure is raise by negative control orifice(A). 45071MC19-1 (3) Operation of low pressure relief When the oil pressure neutral passage(HP) reaches the setting force of spring, the poppet is pushes open; the oil directly flows through passage(HP) to passage(LP) in order to prevent abnormal pressure. 45071MC19-2 2-46