BF135A•BF150A -3. Check for the continuity between the No. 1 (Brown) ter- minal of the water separator water level sensor har- ness side connector and the test harness A-19 termi- nal. 9. EOP switch (high pressure side) line check -1. Disconnect the high pressure side EOP switch 2P con- nector. -2. Check for the continuity between the test harness A-17 terminal and the engine ground. WATER LEVEL SEN- SOR HARNESS SIDE 2P CONNECTOR A-17 VIEWED FROM THE TERMINAL SIDE Is there the continuity? YES – Repair short in the main harness between the high pressure side EOP switch and the ECM. NO – Go to the step 3. Is there the continuity? YES – Perform "8. EOP switch (low pressure side) line check".
NO – Repair open in the main harness between the water level sensor and the ECM. -3. Check for the continuity between the test harness A-17 terminal and the No. 1 (Yellow/Red) terminal of the EOP switch harness side 2P connector. 8. EOP switch (low pressure side) line check -1. Disconnect the low pressure side EOP switch wire. -2. Check for the continuity between the test harness B-14 terminal and the engine ground. EOP SWITCH (HIGH PRESSURE SIDE) HARNESS SIDE 2P CONNECTOR B-14 OPSH (YELLOW/RED) A-17 Is there the continuity? YES – Repair short in the main harness between the low pressure side EOP switch and the ECM. NO – Go to the step 3.
VIEWED FROM THE TERMINAL SIDE Is there the continuity? YES – Connect each connector and recheck. If there is any abnormality, substitute a known- good ECM and recheck. NO – Repair open in the main harness between the high pressure side EOP switch and the ECM. -3. Check for the continuity between the test harness B-14 terminal and the EOP switch harness side (Pink) ter- minal. EOP SWITCH HARNESS SIDE TERMINAL B-14 PINK Is there the continuity? YES – Perform “9. EOP switch (high pressure side) line check”. NO – Repair open in the main harness between the low pressure side EOP switch and the ECM. 5-69