11) Remove the 20 mm hex. nut from the neutral switch, then remove the neutral switch from the neutral switch bracket. [1] 20 mm HEX. NUT [2] NEUTRAL SWITCH BRACKET [3] NEUTRAL SWITCH 12) Remove the 6 x 12 mm flange bolt from the detent arm, then remove the 6 mm washer, detent arm and the detent spring. 6 x 12 Check the detent arm bushing on the detent arm. Replace the detent arm bushing if necessary. [1] 6 mm WASHER [2] DETENT ARM 13) Remove the detent arm bushing from the detent arm. Replace the bushing with a new one on assembly. Check the detent arm for deformation or damage, and replace if necessary. [3] DETENT ARM BUSHING [4] DETENT SPRING b.
INSPECTION • NEUTRAL SWITCH [1] NEUTRAL SWITCH Connect the tester between the terminals and push the switch knob. There must be continuity when the switch knob is pushed, and no continuity when the knob is released. 17-13