Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

111 7 SPN 6~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 6655 3 C E Maintain ECU Power Lamp - Voltage Above Normal, or Shor- ted to High Source ECM 6655 3 C L Maintain ECU Power Lamp - Voltage Above Normal, or Shor- ted to High Source ECM 6655 4 C E Maintain ECU Power Lamp - Voltage Below Normal, or Shor- ted to Low Source ECM 6655 4 C L Maintain ECU Power Lamp - Voltage Below Normal, or Shor- ted to Low Source ECM 666 5 C E Injector Solenoid Driver Cylinder 16 Circuit - Current below nor- mal or open circuit ECM 666 5 C L Injector Solenoid Driver Cylinder 16 Circuit - Current below nor- mal or open circuit ECM 666 5 C F Injector Solenoid Driver Cylinder 16 Circuit - Current below nor- mal or open circuit ECM 6713 13 C E Variable Geometry Turbocharg- er Actuator Software - Out of Calibration ECM 6713 13 C L Variable Geometry Turbocharg- er Actuator Software - Out of Calibration ECM 6713 31 C E Variable Geometry Turbocharg- er Actuator Software - Condition Exists ECM 6713 31 C L Variable Geometry Turbocharg- er Actuator Software - Condition Exists ECM 6713 13 C F Variable Geometry Turbocharg- er Actuator Software - Out of Calibration ECM 6713 31 C F Variable Geometry Turbocharg- er Actuator Software - Condition Exists ECM 6713 9 C F VGT Actuator Driver Circuit - Abnormal update rate ECM 6713 9 C E VGT Actuator Driver Circuit - Abnormal update rate ECM 6713 9 C L VGT Actuator Driver Circuit - Abnormal update rate ECM 676 5 P E Engine Glow Plug Relay:

Cur- rent Below Normal ECM 676 5 P L Engine Glow Plug Relay: Cur- rent Below Normal ECM 676 6 P E Engine Glow Plug Relay: Cur- rent Above Normal ECM 676 6 P L Engine Glow Plug Relay: Cur- rent Above Normal ECM 676 19 P E Engine Glow Plug Relay: Data Error ECM 676 19 P L Engine Glow Plug Relay: Data Error ECM 677 3 C E Starter Relay Driver Circuit - Voltage above normal, or shor- ted to high source ECM 677 3 C L Starter Relay Driver Circuit - Voltage above normal, or shor- ted to high source ECM 677 3 P E Engine Starter Motor Relay : Voltage Above Normal ECM 677 3 P L Engine Starter Motor Relay :

Voltage Above Normal ECM 677 3 S E Starter actuator, short circuit to +24V ECM 677 3 S L Starter actuator, short circuit to +24V continued.......... ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 677 4 C E Starter Relay Driver Circuit - Voltage below normal, or shor- ted to low source ECM 677 4 C L Starter Relay Driver Circuit - Voltage below normal, or shor- ted to low source ECM 677 4 S E Starter actuator, short circuit to ground ECM 677 4 S L Starter actuator, short circuit to ground ECM 677 5 P E Engine Starter Motor Relay: Current Below Normal ECM 677 5 P L Engine Starter Motor Relay:

Current Below Normal ECM 677 5 S E Starter actuator, open load ECM 677 5 S L Starter actuator, open load ECM 677 6 P E Engine Starter Motor Relay : Current Above Normal ECM 677 6 P L Engine Starter Motor Relay :

Current Above Normal ECM 677 0 S E Unintentional starter activation while moving or idling ECM 677 0 S F Unintentional starter activation while moving or idling ECM 677 0 S L Unintentional starter activation while moving or idling ECM 677 19 S E Starter motor demand defect via CAN ECM 677 19 S F Starter motor demand defect via CAN ECM 677 19 S L Starter motor demand defect via CAN ECM 677 2 S E Starter actuator, faulty ECM 677 2 S F Starter actuator, faulty ECM 677 2 S L Starter actuator, faulty ECM 677 3 S F Starter actuator, short circuit to +24V ECM 677 4 S F Starter actuator, short circuit to ground ECM 677 5 S F Starter actuator, open load ECM 677 7 S E Starter actuator, blind start ECM 677 7 S F Starter actuator, blind start ECM 677 7 S L Starter actuator, blind start ECM 677 8 S F Activates the starter ECM 677 3 C F Starter Solenoid Lockout Relay Driver Circuit :

Starter Relay Cir- cuit - Voltage Above Normal, or Shorted to High Source ECM 677 4 C F Starter Solenoid Lockout Relay Driver Circuit : Starter Relay Cir- cuit - Voltage Below Normal, or Shorted to Low Source ECM 678 3 P E ECU 8V DC Supply : Voltage Above Normal ECM 678 3 P L ECU 8V DC Supply : Voltage Above Normal ECM 678 4 P E ECU 8V DC Supply : Voltage Below Normal ECM 678 4 P L ECU 8V DC Supply : Voltage Below Normal ECM 6799 3 C E Fan Blade Pitch Position Sensor Circuit - Voltage Above Normal, or Shorted to High Source ECM 6799 3 C L Fan Blade Pitch Position Sensor Circuit - Voltage Above Normal, or Shorted to High Source continued..........