Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

37 3 SPN 2~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description MCU 221 6 * L ATT Relief Setting EPPR 1 Valve-Cur- rent Above Normal Or Grounded Cir- cuit MCU 222 5 * E ATT Relief Setting EPPR 2 Valve-Volt- age Below Normal, Or Shorted To Low Source MCU 222 5 * L ATT Relief Setting EPPR 2 Valve-Volt- age Below Normal, Or Shorted To Low Source MCU 222 6 * E ATT Relief Setting EPPR 2 Valve-Cur- rent Above Normal Or Grounded Cir- cuit MCU 222 6 * L ATT Relief Setting EPPR 2 Valve-Cur- rent Above Normal Or Grounded Cir- cuit TCU 23 * * L S.C. TO BATTERY VOLTAGE AT LOAD SENSOR INPUT TCU 23 * * F S.C.

TO BATTERY VOLTAGE AT LOAD SENSOR INPUT EH- CU 2304 5 * L Boom Up EPPR Valve Input Current Below Normal or Open Circuit EH- CU 2304 6 * L Boom Up EPPR Valve Input Current Above Normal or Grounded Circuit EH- CU 2304 0 * L Boom Up EPPR Valve Input Value Above Normal Operation Range EH- CU 2304 1 * L Boom Up EPPR Valve Input Value Be- low Normal Operation Range EH- CU 2304 14 * L Boom Up EPPR Valve Block Parame- ter Invalid EH- CU 2305 5 * L Boom Down EPPR Valve Input Cur- rent Below Normal or Open Circuit EH- CU 2305 6 * L Boom Down EPPR Valve Input Cur- rent Above Normal or Grounded Cir- cuit EH- CU 2305 0 * L Boom Down EPPR Valve Input Value Above Normal Operation Range EH- CU 2305 1 * L Boom Down EPPR Valve Input Value Below Normal Operation Range EH- CU 2305 14 * L Boom Down EPPR Valve Block Pa- rameter Invalid EH- CU 2306 5 * L Bucket In EPPR Valve Input Current Below Normal or Open Circuit EH- CU 2306 6 * L Bucket In EPPR Valve Input Current Above Normal or Grounded Circuit EH- CU 2306 0 * L Bucket In EPPR Valve Input Value Above Normal Operation Range EH- CU 2306 1 * L Bucket In EPPR Valve Input Value Be- low Normal Operation Range EH- CU 2306 14 * L Bucket In EPPR Valve Block Parame- ter Invalid EH- CU 2307 5 * L Bucket Dump EPPR Valve Input Cur- rent Below Normal or Open Circuit EH- CU 2307 6 * L Bucket Dump EPPR Valve Input Cur- rent Above Normal or Grounded Cir- cuit EH- CU 2307 0 * L Bucket Dump EPPR Valve Input Value Above Normal Operation Range EH- CU 2307 1 * L Bucket Dump EPPR Valve Input Value Below Normal Operation Range EH- CU 2307 14 * L Bucket Dump EPPR Valve Block Pa- rameter Invalid EH- CU 2308 0 * L Aux.

Up EPPR Valve Input Value Above Normal Operation Range EH- CU 2308 1 * L Aux. Up EPPR Valve Input Value Be- low Normal Operation Range EH- CU 2308 14 * L Aux. Up EPPR Valve Block Parameter Invalid EH- CU 2308 5 * L Aux. Up EPPR Valve Input Current Below Normal or Open Circuit continued.......... ...........continued TYPE SPN FMI En- gine Ma- chine type Description EH- CU 2308 6 * L Aux. Up EPPR Valve Input Current Above Normal or Grounded Circuit EH- CU 2309 0 * L Aux. Down EPPR Valve Input Data Above Normal Operation Range EH- CU 2309 1 * L Aux. Down EPPR Valve Input Data Below Normal Operation Range EH- CU 2309 14 * L Aux. Down EPPR Valve Block Param- eter Invalid EH- CU 2309 5 * L Aux.

Down EPPR Valve Input Current Below Normal or Open Circuit EH- CU 2309 6 * L Aux.

Down EPPR Valve Input Current Above Normal or Grounded Circuit EH- CU 2311 0 * L Boom Joystick Position Input Value Above Normal Operation Range EH- CU 2311 1 * L Boom Joystick Position Input Value Below Normal Operation Range EH- CU 2311 2 * L Boom Joystick Position Signal Error EH- CU 2311 3 * L Boom Joystick Position Input Voltage Above Normal or Shorted to High Source EH- CU 2311 4 * L Boom Joystick Position Input Voltage Below Normal or Shorted to Low Source EH- CU 2311 13 * L Boom Joystick Position Control Block Out of Calibration EH- CU 2311 14 * L Boom Joystick Position Control Block Parameter Invalid EH- CU 2311 31 * L Boom Joysitck Position Signal Redun- dancy Lost EH- CU 2313 0 * L Bucket Joystick Position Input Value Above Normal Operation Range EH- CU 2313 1 * L Bucket Joystick Position Input Value Below Normal Operation Range EH- CU 2313 2 * L Bucket Joystick Position Signal Error EH- CU 2313 3 * L Bucket Joystick Position Input Voltage Above Normal or Shorted to High Source EH- CU 2313 4 * L Bucket Joystick Position Input Voltage Below Normal or Shorted to Low Source EH- CU 2313 13 * L Bucket Joystick Position Control Block Out of Calibration EH- CU 2313 14 * L Bucket Joystick Position Control Block Parameter Invalid EH- CU 2313 31 * L Bucket Joysitck Position Signal Re- dundancy Lost EH- CU 2315 0 * L Aux Joystick Position Input Value Above Normal Operation Range EH- CU 2315 1 * L Aux Joystick Position Input Value Be- low Normal Operation Range EH- CU 2315 13 * L Aux Joystick Position Control Block Out of Calibration EH- CU 2315 14 * L Aux Joystick Position Control Block Parameter Invalid EH- CU 2315 2 * L Aux Joystick Position Signal Error EH- CU 2315 3 * L Aux Joystick Position Input Voltage Above Normal or Shorted to High Source EH- CU 2315 31 * L Aux Joysitck Position Signal Redun- dancy Lost EH- CU 2315 4 * L Aux Joystick Position Input Voltage Below Normal or Shorted to Low Source EH- CU 2317 9 * L Communication Timeout between EH- CU and Steering Joystick continued..........