60 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description in the valve block for exhaust gas af- tertreatment V184. ECM 3480 8 S E The air pressure is too high when the air control valve in the valve block for exhaust gas aftertreatment is open. ECM 3480 8 S L The air pressure is too high when the air control valve in the valve block for exhaust gas aftertreatment is open. ECM 3480 9 S E The air pressure in the valve block for exhaust gas aftertreatment is not increasing even though the air con- trol valve is open. ECM 3480 9 S L The air pressure in the valve block for exhaust gas aftertreatment is not increasing even though the air con- trol valve is open.

ECM 3480 10 S F Reductant circuit pressure ECM 3480 2 S F Fault in doser valve ECM 3480 3 S F Fault in dose valve sensor ECM 3480 4 S F Fault in dose valve sensor ECM 3480 8 S F Reductant circuit pressure ECM 3480 9 S F Reductant circuit pressure ECM 3481 16 C F Aftertreatment Fuel Rate - Data Val- id But Above Normal Operating Range - Moderately Severe Level ECM 3481 16 C E Aftertreatment Fuel Rate - Data Val- id But Above Normal Operating Range - Moderately Severe Level ECM 3481 16 C L Aftertreatment Fuel Rate - Data Val- id But Above Normal Operating Range - Moderately Severe Level ECM 3482 13 C F Aftertreatment Fuel Shutoff Valve Swapped - Out of Calibration ECM 3482 16 C F Aftertreatment Fuel Shutoff Valve - Data Valid But Above Normal Oper- ating Range - Moderately Severe ECM 3482 2 C F Aftertreatment Fuel Shutoff Valve - Data erratic, intermittent or incorrect ECM 3482 3 C F Aftertreatment Fuel Shutoff Valve Circuit - Voltage above normal, or shorted to high source ECM 3482 4 C F Aftertreatment Fuel Shutoff Valve Circuit - Voltage below normal, or shorted to low source ECM 3482 7 C F Aftertreatment Fuel Shutoff Valve - Mechanical system not responding or out of adjustment ECM 3482 13 C E Aftertreatment Fuel Shutoff Valve Swapped - Out of Calibration ECM 3482 13 C L Aftertreatment Fuel Shutoff Valve Swapped - Out of Calibration ECM 3482 16 C E Aftertreatment Fuel Shutoff Valve - Data Valid But Above Normal Oper- ating Range - Moderately Severe ECM 3482 16 C L Aftertreatment Fuel Shutoff Valve - Data Valid But Above Normal Oper- ating Range - Moderately Severe ECM 3482 2 C E Aftertreatment Fuel Shutoff Valve - Data erratic, intermittent or incorrect ECM 3482 2 C L Aftertreatment Fuel Shutoff Valve - Data erratic, intermittent or incorrect ECM 3482 3 C E Aftertreatment Fuel Shutoff Valve Circuit - Voltage above normal, or shorted to high source ECM 3482 3 C L Aftertreatment Fuel Shutoff Valve Circuit - Voltage above normal, or shorted to high source continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3482 4 C E Aftertreatment Fuel Shutoff Valve Circuit - Voltage below normal, or shorted to low source ECM 3482 4 C L Aftertreatment Fuel Shutoff Valve Circuit - Voltage below normal, or shorted to low source ECM 3482 7 C E Aftertreatment Fuel Shutoff Valve - Mechanical system not responding or out of adjustment ECM 3482 7 C L Aftertreatment Fuel Shutoff Valve - Mechanical system not responding or out of adjustment ECM 3485 2 S E SCR main unit, air pressure sensor after orifice circuit supply ECM 3485 2 S L SCR main unit, air pressure sensor after orifice circuit supply ECM 3485 3 S E SCR main unit, air pressure sensor after orifice circuit high ECM 3485 3 S L SCR main unit, air pressure sensor after orifice circuit high ECM 3485 4 S E SCR main unit, air pressure sensor after orifice circuit low ECM 3485 4 S L SCR main unit, air pressure sensor after orifice circuit low ECM 3485 7 S E SCR, air circuit blocked ECM 3485 7 S L SCR, air circuit blocked ECM 3485 1 S F SCR main unit, air pressure too low ECM 3485 1 S E SCR main unit, air pressure too low ECM 3485 18 S F EEC, air supply low ECM 3485 1 S L SCR main unit, air pressure too low ECM 3485 2 S F SCR main unit, air pressure sensor after orifice circuit supply ECM 3485 18 S E EEC, air supply low ECM 3485 20 S F SCR main unit, air pressure sensor after orifice plausible error ECM 3485 18 S L EEC, air supply low ECM 3485 3 S F SCR main unit, air pressure sensor after orifice circuit high ECM 3485 4 S F SCR main unit, air pressure sensor after orifice circuit low ECM 3485 7 S F SCR, air circuit blocked ECM 3485 20 S E SCR main unit, air pressure sensor after orifice plausible error ECM 3485 9 S F SCR main unit, air pressure sensor after orifice performance ECM 3485 20 S L SCR main unit, air pressure sensor after orifice plausible error ECM 3485 9 S E SCR main unit, air pressure sensor after orifice performance ECM 3485 9 S L SCR main unit, air pressure sensor after orifice performance ECM 3489 3 C F Aftertreatment #1 Air Enable Actua- tor Voltage Above Normal, or Shor- ted to High Source.

High signal volt- age has been detected at the cata- lyst air solenoid circuit. ECM 3489 4 C F Aftertreatment #1 Air Enable Actua- tor Voltage Below Normal, or Shor- ted to Low Source. Low signal volt- age has been detected at the cata- lyst air solenoid circuit. ECM 3490 3 C F Aftertreatment Purge Air Actuator Circuit - Voltage above normal, or shorted to high source ECM 3490 4 C F Aftertreatment Purge Air Actuator Circuit - Voltage below normal, or shorted to low source continued..........