73 5 SPN 4~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description erating Range - Moderately Severe Lev- el ECM 4360 16 C L Aftertreatment 1 SCR Intake Tempera- ture - Data Valid But Above Normal Op- erating Range - Moderately Severe Lev- el ECM 4360 16 P E Aftertreatment #1 SCR Catalyst Intake Gas Temperature : High - moderate se- verity (2) ECM 4360 16 P L Aftertreatment #1 SCR Catalyst Intake Gas Temperature : High - moderate se- verity (2) ECM 4360 18 P E Aftertreatment #1 SCR Catalyst Intake Gas Temperature : Low - moderate se- verity (2) ECM 4360 18 P L Aftertreatment #1 SCR Catalyst Intake Gas Temperature :
Low - moderate se- verity (2) ECM 4360 3 C E Aftertreatment 1 SCR Intake Tempera- ture Sensor Circuit - Voltage above nor- mal, or shorted to high source ECM 4360 3 C L Aftertreatment 1 SCR Intake Tempera- ture Sensor Circuit - Voltage above nor- mal, or shorted to high source ECM 4360 3 P E Aftertreatment #1 SCR Catalyst Intake Gas Temperature : Voltage Above Nor- mal ECM 4360 3 P L Aftertreatment #1 SCR Catalyst Intake Gas Temperature :
Voltage Above Nor- mal ECM 4360 4 C E Aftertreatment 1 SCR Intake Tempera- ture Sensor Circuit - Voltage below nor- mal, or shorted to low source ECM 4360 4 C L Aftertreatment 1 SCR Intake Tempera- ture Sensor Circuit - Voltage below nor- mal, or shorted to low source ECM 4360 4 P E Aftertreatment #1 SCR Catalyst Intake Gas Temperature : Voltage Below Nor- mal ECM 4360 4 P L Aftertreatment #1 SCR Catalyst Intake Gas Temperature :
Voltage Below Nor- mal ECM 4360 15 C E Aftertreatment 1 SCR Intake Tempera- ture - Data Valid But Above Normal Op- erating Range - Least Severe ECM 4360 15 C L Aftertreatment 1 SCR Intake Tempera- ture - Data Valid But Above Normal Op- erating Range - Least Severe ECM 4360 17 P E Aftertreatment #1 SCR Catalyst Intake Gas Temperature : Low - least severe (1) ECM 4360 17 P L Aftertreatment #1 SCR Catalyst Intake Gas Temperature :
Low - least severe (1) ECM 4360 2 C E Aftertreatment 1 SCR Intake Tempera- ture Sensor - Data erratic, intermittent or incorrect ECM 4360 2 C L Aftertreatment 1 SCR Intake Tempera- ture Sensor - Data erratic, intermittent or incorrect ECM 4360 20 P E Aftertreatment #1 SCR Catalyst Intake Gas Temperature : Data Drifted High ECM 4360 20 P L Aftertreatment #1 SCR Catalyst Intake Gas Temperature :
Data Drifted High ECM 4363 0 C E Aftertreatment 1 SCR Outlet Tempera- ture - Data valid but above normal op- erational range - Most Severe ECM 4363 0 C L Aftertreatment 1 SCR Outlet Tempera- ture - Data valid but above normal op- erational range - Most Severe ECM 4363 0 C F Aftertreatment 1 SCR Outlet Tempera- ture - Data valid but above normal op- erational range - Most Severe continued..........
...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 4363 16 C F Aftertreatment 1 SCR Outlet Tempera- ture - Data Valid But Above Normal Op- erating Range - Moderately Severe Lev- el ECM 4363 16 C E Aftertreatment 1 SCR Outlet Tempera- ture - Data Valid But Above Normal Op- erating Range - Moderately Severe Lev- el ECM 4363 16 C L Aftertreatment 1 SCR Outlet Tempera- ture - Data Valid But Above Normal Op- erating Range - Moderately Severe Lev- el ECM 4363 2 C F Aftertreatment 1 SCR Outlet Tempera- ture Sensor - Data erratic, intermittent or incorrect ECM 4363 3 C F Aftertreatment 1 SCR Outlet Tempera- ture Sensor Circuit - Voltage above nor- mal, or shorted to high source ECM 4363 4 C F Aftertreatment 1 SCR Outlet Tempera- ture Sensor Circuit - Voltage below nor- mal, or shorted to low source ECM 4363 3 C E Aftertreatment 1 SCR Outlet Tempera- ture Sensor Circuit - Voltage above nor- mal, or shorted to high source ECM 4363 3 C L Aftertreatment 1 SCR Outlet Tempera- ture Sensor Circuit - Voltage above nor- mal, or shorted to high source ECM 4363 4 C E Aftertreatment 1 SCR Outlet Tempera- ture Sensor Circuit - Voltage below nor- mal, or shorted to low source ECM 4363 4 C L Aftertreatment 1 SCR Outlet Tempera- ture Sensor Circuit - Voltage below nor- mal, or shorted to low source ECM 4363 2 C E Aftertreatment 1 SCR Outlet Tempera- ture Sensor - Data erratic, intermittent or incorrect ECM 4363 2 C L Aftertreatment 1 SCR Outlet Tempera- ture Sensor - Data erratic, intermittent or incorrect ECM 4364 18 C F Aftertreatment SCR Catalyst Conversion Efficiency - Data Valid But Below Normal Operating Range - Moderately Severe Level ECM 4364 18 C E Aftertreatment SCR Catalyst Conversion Efficiency - Data Valid But Below Normal Operating Range - Moderately Severe Level ECM 4364 18 C L Aftertreatment SCR Catalyst Conversion Efficiency - Data Valid But Below Normal Operating Range - Moderately Severe Level ECM 4364 18 P E Aftertreatment #1 SCR Catalyst Conver- sion Efficiecy :
Low - moderate severity (2) ECM 4364 18 P L Aftertreatment #1 SCR Catalyst Conver- sion Efficiecy : Low - moderate severity (2) ECM 4364 31 C E Aftertreatment 1 SCR Conversion Effi- ciency - Condition Exists ECM 4364 31 C L Aftertreatment 1 SCR Conversion Effi- ciency - Condition Exists ECM 4364 17 C E Aftertreatment SCR Catalyst Conversion Efficiency - Data Valid But Below Normal Operating Range - Moderately Severe Level ECM 4364 17 C L Aftertreatment SCR Catalyst Conversion Efficiency - Data Valid But Below Normal Operating Range - Moderately Severe Level ECM 4364 2 P E Aftertreatment #1 SCR Catalyst Conver- sion Efficiecy :
Erratic, Intermittent ,or In- corrcet ECM 4364 2 P L Aftertreatment #1 SCR Catalyst Conver- sion Efficiecy : Erratic, Intermittent ,or In- corrcet continued..........