Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

94 6 SPN 5~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 5706 3 S L Fault in reductant pump control. ECM 5706 4 S E Fault in reductant pump control. ECM 5706 4 S L Fault in reductant pump control. ECM 5706 5 P E Aftertreatment #1 Diesel Exhaust Fluid Pump Heater : Current Below Normal ECM 5706 5 P L Aftertreatment #1 Diesel Exhaust Fluid Pump Heater : Current Below Normal ECM 5706 6 P E Aftertreatment #1 Diesel Exhaust Fluid Pump Heater : Current Above Normal ECM 5706 6 P L Aftertreatment #1 Diesel Exhaust Fluid Pump Heater : Current Above Normal ECM 5706 6 S E Fault in reductant pump control. ECM 5706 6 S L Fault in reductant pump control.

ECM 5706 3 S F Reductant pump control ECM 5706 4 S F Reductant pump control ECM 5706 6 S F Reductant pump control MCU 5730 0 * L DIFFERENTIAL PRESSURE OIL FILTER TCU measured a voltage at differential pressure switch out of the allowed range MCU 5740 2 * L SLIPPAGE AT CONVERTER LOCK- UP CLUTCH TCU calculates a differ- ential speed at closed converter lock- up clutch. If this calculated value is out of range, TCU interprets this as slipping clutch.

ECM 5741 2 C F Aftertreatment 1 Outlet Soot - Data erratic, intermittent or incorrect ECM 5741 3 C F Aftertreatment 1 Outlet Soot Sensor - Voltage Above Normal, or Shorted to High Source ECM 5741 4 C F Aftertreatment 1 Outlet Soot Sensor - Voltage below normal, or shorted to low source ECM 5741 2 C E Aftertreatment 1 Outlet Soot - Data erratic, intermittent or incorrect ECM 5741 2 C L Aftertreatment 1 Outlet Soot - Data erratic, intermittent or incorrect ECM 5741 3 C E Aftertreatment 1 Outlet Soot Sensor - Voltage Above Normal, or Shorted to High Source ECM 5741 3 C L Aftertreatment 1 Outlet Soot Sensor - Voltage Above Normal, or Shorted to High Source ECM 5741 4 C E Aftertreatment 1 Outlet Soot Sensor - Voltage below normal, or shorted to low source ECM 5741 4 C L Aftertreatment 1 Outlet Soot Sensor - Voltage below normal, or shorted to low source ECM 5742 11 C F Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Root Cause Not Known ECM 5742 12 C F Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Bad intelligent device or component ECM 5742 16 C F Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module- Da- ta Valid But Above Normal Operating Range ECM 5742 3 C F Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Voltage Above Normal, or Shorted to high source ECM 5742 4 C F Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Voltage below normal, or shorted to low source continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 5742 9 C F Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Abnormal update rate ECM 5742 3 C E Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Voltage Above Normal, or Shorted to high source ECM 5742 3 C L Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Voltage Above Normal, or Shorted to high source ECM 5742 4 C E Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Voltage below normal, or shorted to low source ECM 5742 4 C L Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Voltage below normal, or shorted to low source ECM 5742 11 C E Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Root Cause Not Known ECM 5742 11 C L Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Root Cause Not Known ECM 5742 12 C E Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Bad intelligent device or component ECM 5742 12 C L Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Bad intelligent device or component ECM 5742 16 C E Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module- Da- ta Valid But Above Normal Operating Range ECM 5742 16 C L Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module- Da- ta Valid But Above Normal Operating Range ECM 5742 9 C E Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Abnormal update rate ECM 5742 9 C L Aftertreatment Diesel Particulate Fil- ter Temperature Sensor Module - Abnormal update rate ECM 5743 11 C F Aftertreatment Selective Catalytic Reduction Temperature Sensor Mod- ule - Root Cause Not Known ECM 5743 12 C F Aftertreatment Selective Catalytic Reduction Temperature Sensor Mod- ule - Bad intelligent device or compo- nent ECM 5743 16 C F Aftertreatment Selective Catalytic Reduction Temperature Sensor Mod- ule - Data Valid But Above Normal ECM 5743 3 C F Aftertreatment Selective Catalytic Reduction Temperature Sensor Mod- ule - Voltage Above Normal, or Shor- ted to high source ECM 5743 4 C F Aftertreatment Selective Catalytic Reduction Temperature Sensor Mod- ule - Voltage below normal, or Shor- ted to low source ECM 5743 9 C F Aftertreatment Selective Catalytic Reduction Temperature Sensor Mod- ule - Abnormal update rate ECM 5743 2 S E Reductant tank temperature sensor, not plausible ECM 5743 2 S L Reductant tank temperature sensor, not plausible ECM 5743 3 C E Aftertreatment Selective Catalytic Reduction Temperature Sensor Mod- ule - Voltage Above Normal, or Shor- ted to high source ECM 5743 3 C L Aftertreatment Selective Catalytic Reduction Temperature Sensor Mod- continued..........