97 6 SPN 5~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description switched off VPS1 and measured VPS1 is still on MCU 5830 3 * L HIGH VOLTAGE AT BATTERY measured voltage at power supply is higher than 18 V (12V device) / high- er than 32.5 V (24V device) ECM 5835 3 C E Aftertreatment 1 Outlet Soot Sensor - Voltage Above Normal, or Shorted to High Source ECM 5835 3 C L Aftertreatment 1 Outlet Soot Sensor - Voltage Above Normal, or Shorted to High Source ECM 5835 4 C E Aftertreatment 1 Outlet Soot Sensor - Voltage below normal, or shorted to low source ECM 5835 4 C L Aftertreatment 1 Outlet Soot Sensor - Voltage below normal, or shorted to low source ECM 5838 31 C F EGR Valve Malfunction - Condition Exists ECM 5838 31 C E EGR Valve Malfunction - Condition Exists ECM 5838 31 C L EGR Valve Malfunction - Condition Exists ECM 5839 31 C F Diesel Exhaust Fluid Consumption Malfunction - Condition Exists ECM 5839 31 C E Diesel Exhaust Fluid Consumption Malfunction - Condition Exists ECM 5839 31 C L Diesel Exhaust Fluid Consumption Malfunction - Condition Exists MCU 5840 2 * L ERROR VALVE POWER SUPPLY VPS2 TCU switched on VPS2 and measured VPS2 is off or TCU switched off ECM 5840 31 C F Diesel Exhaust Fluid Dosing Mal- function - Condition Exists ECM 5840 31 C E Diesel Exhaust Fluid Dosing Mal- function - Condition Exists ECM 5840 31 C L Diesel Exhaust Fluid Dosing Mal- function - Condition Exists ECM 5841 1 S E SCR main unit, reductant quality too low ECM 5841 1 S L SCR main unit, reductant quality too low ECM 5841 31 C F Diesel Exhaust Fluid Quality Mal- function - Condition Exists ECM 5841 31 C E Diesel Exhaust Fluid Quality Mal- function - Condition Exists ECM 5841 31 C L Diesel Exhaust Fluid Quality Mal- function - Condition Exists ECM 5841 1 S F SCR main unit, reductant quality too low ECM 5842 31 C F SCR Monitoring System Malfunction - Condition Exists ECM 5842 14 C E SCR Monitoring System Malfunction - Special Instructions ECM 5842 14 C L SCR Monitoring System Malfunction - Special Instructions ECM 5842 31 C E SCR Monitoring System Malfunction - Condition Exists ECM 5842 31 C L SCR Monitoring System Malfunction - Condition Exists ECM 5848 12 C E Aftertreatment 1 SCR Intermediate NH3 Sensor - Bad Intelligent Device or Component ECM 5848 12 C L Aftertreatment 1 SCR Intermediate NH3 Sensor - Bad Intelligent Device or Component ECM 5848 13 C E Aftertreatment 1 SCR Intermediate NH3 Sensor - Out of Calibration continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 5848 13 C L Aftertreatment 1 SCR Intermediate NH3 Sensor - Out of Calibration ECM 5848 4 C E Aftertreatment 1 SCR Intermediate NH3 Sensor - Voltage Below Normal or Shorted to Low Source ECM 5848 4 C L Aftertreatment 1 SCR Intermediate NH3 Sensor - Voltage Below Normal or Shorted to Low Source ECM 5851 16 C E Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply - Da- ta Valid But Above Normal Operating Range - Moderately Severe Level ECM 5851 16 C L Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply - Da- ta Valid But Above Normal Operating Range - Moderately Severe Level ECM 5851 18 C E Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply - Da- ta Valid But Below Normal Operating Range - Moderately Severe Level ECM 5851 18 C L Aftertreatment 1 SCR Intermediate NH3 Gas Sensor Power Supply - Da- ta Valid But Below Normal Operating Range - Moderately Severe Level MCU 5860 3 * L S.C.

TO BATTERY VOLTAGE AT DISPLAY OUTPUT TCU sends data to the display and measures allways a high voltage level on the connector MCU 5860 4 * L S.C. TO GROUND AT DISPLAY OUTPUT TCU sends data to the dis- play and measures allways a high voltage level on the connector MCU 5890 2 * L GENERAL EEPROM FAULT TCU can't read non volatile memory TCU 59 * * L ENGINE SPEED LIMIT FUNCTION DOES NOT WORK PROPERLY TCU 59 * * F TEST MODE SIGNAL ECM 590 2 S F Status signal which indicates the cur- rent mode of operation of the idle shutdown timer system. MCU 5900 13 * L CONFIGURATION LOST TCU has lost the correct configuration and can't control the transmission.

MCU 5910 13 * L APPLICATION ERROR something of this application is wrong ECM 593 31 P E Engine Idle Shutdown has Shutdown Engine ECM 593 31 P L Engine Idle Shutdown has Shutdown Engine MCU 5930 7 * L CLUTCH FAILURE AEB was not able to adjust clutch filling parame- ters MCU 5930 13 * L CLUTCH ADJUSTMENT DATA LOST OR INCHPEDAL CALIBRA- TION DATA LOST TCU was not able to read correct clutch adjustment pa- rameters ECM 594 31 P E Engine Idle Shutdown Driver Alert Mode ECM 594 31 P L Engine Idle Shutdown Driver Alert Mode MCU 5940 11 * L SUBSTITUTE CLUTCH CONTROL ECM 596 13 C F Cruise Control Enable Switch - Out of Calibration ECM 596 2 C F Cruise Control Enable Switch - Data erratic, intermittent or incorrect ECM 596 7 C F Cruise Control Enable Switch - Me- chanical system not responding or out of adjustment ECM 596 13 C E Cruise Control Enable Switch - Out of Calibration ECM 596 13 C L Cruise Control Enable Switch - Out of Calibration continued..........