JCB — Air Conditioning System Diagnosis

www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 10 - 7 10 - 7 Fault Finding Air Conditioning - System Diagnosis (cont'd) Compressor Malfunction Gauge Readings: Low Side Gauge - High. High Side Gauge - Low. Diagnosis: Internal compressor leak or compressor mechanically broken. Correction: 1. Evacuate A/C system. 2. Repair or replace compressor. 3. Charge system with R-134a. 4. Operate system and check performance.

LOW SIDE (Blue) HIGH SIDE (Red) High Low 60 7 0 3501201101000908 150 2 0 0 250 20304050 350003 100 50 400 10 0 0 3 0 450 500 A268090 LOW SIDE - 4.9 bar (5.0 kgf/cm2)(71 lbf/in2) HIGH SIDE - 8.3 bar (8.5 kgf/cm2)(121 lbf/in2) Some Moisture in the System Gauge Readings: Low Side Gauge - Normal, then sometimes drops to below zero. High Side Gauge - Normal, then sometimes goes high. Diagnosis: Moisture in system freezes, temporarily stopping cycle, normal system operation returns when ice melts. Correction: 1. Evacuate A/C system. 2. Replace receiver-drier. 3. Remove moisture by repeatedly evacuating system. 4. Charge system with R-134a. 5. Operate system and check performance.

LOW SIDE (Blue) HIGH SIDE (Red) Normal to low Normal to high 60 7 0 3501201101000908 150 2 0 0 250 20304050 350003 100 50 400 10 0 0 3 0 450 500 A268020 LOW SIDE - -2.1 bar (-2.1 kgf/cm2)(-30 lbf/in2) HIGH SIDE - 14.8 bar (15.0 kgf/cm2)(214 lbf/in2)