JCB — Checking Refrigerant Charge Level

Air Conditioning Checking Refrigerant Charge Level Leak Testing The pressure in the system, i.e. the refrigerant charge level can be determined by checking the state of refrigerant at the receiver drier sight glass. Note : The refrigerant is heavier than air and will leak downwards from the defective component. Check in still conditions but in a well ventilated area. If the level of charge is correct the sight glass will be clear. If the charge is low bubbles will be seen. Bubbles may also be an indication of inadequate cooling, due to a restriction of air flow around the condenser coil. Recharging of the system should be carried out by an air conditioning engineer.

Check refrigerant charge level as follows: Hose or pipe connections are likely leakage points of any refrigerant circuit. To test for leaks in the high pressure side of the system i.e. from the compressor output to the expansion valve, run the air conditioning for a few minutes then switch off the engine and test for leakage using an electronic leak detector. 1 Park the machine on firm, level ground. Lower the backhoe and loader to the ground. To test for leakage in the low pressure side of the system, switch off the air conditioning and leave for a few minutes before testing. ! WARNING Leak testing in Air Conditioning systems should be carried out only in a well ventilated area.

BF 1-2 2 Remove the starter key. 3 Remove the front grille. ! WARNING When the engine is turning, there are parts rotating in the engine compartment. Before starting this job make sure that you have no loose clothing (cuffs, ties etc) which could get caught in rotating parts. Tightening Leaking Hoses When the engine is turning, keep clear of rotating parts. 2-3-3-10 ! WARNING The air conditioning system is a closed loop system and contains pressurised refrigerant. No part of the system must be disconnected except by a qualified refrigeration engineer. 4-3-4-1 4 Start the engine and run at idle. Switch air conditioning ON to circulate refrigerant.

5 Check refrigerant charge level at sight glass A . The refrigerant hoses have crimped ferrule end fittings. The hose connectors have an 'O' ring seal which compresses when the connection is tight, creating an air tight seal. A Hoses are used to connect the inlets and outlets of the compressor, condenser, receiver drier and expansion valve (the evaporator coil is connected to the expansion valve within the air conditioning unit using rigid pipes). If leakage is detected from a hose connector, either by means of an electronic leak detector or soapy water, tighten the connector up and repeat the leakage test.

If leakage is still evident, it will be necessary to de-gas the system and renew the connector 'O' ring seal. The 'O' rings used on an R-134a refrigerant system are of an HNBR compound and are colour coded green. These 'O' rings must be used as some 'O' ring materials can become porous to R-134a systems, resulting in leakage. S190460 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 20 - 1 20 - 1 Service Procedures