JCB — Binary Pressure Switch - Removal and Replacement

www.WorkshopManuals.co.uk Binary Pressure Switch - Removal and Replacement The pressure switch is located adjacent to the expansion valve S on the HVAC/air conditioning unit, beneath the right hand side console. ! WARNING Goggles and rubber gloves must be worn when pressure switches are removed or fitted. A small amount of refrigerant is released which can be harmful to the skin and eyes. BF 1-10 Removal 1 Disconnect the battery. 2 Gain access to the HVAC unit by removing the right hand side console, refer to HVAC/Air Conditioning Unit - Removal and Replacement Step 2. 3 Disconnect the electrical connections and unscrew the pressure switch.

Replacement 1 Screw the pressure switch into the pressure switch port and torque tighten sufficiently to form a gas-tight seal. 2 Run the air conditioning and check the pressure switches for leaks. If any leaks are found, tighten the pressure switch further until the leaking stops. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 30 - 6 30 - 6 Air Conditioning