JCB — Fault Finding

Fault Finding Chart A - No Servo Controls (system fails to operate) START See Electrical Switches, Seat Mounted Microswitch - Adjustment. Does system function if the 'mode' switch is operated? YES Check seat mounted micro switch function and condition of associated wiring for damage. Repair or renew as applicable. NO Is the supply valve solenoid coil faulty? YES Renew coil. NO Is the relevant electrical fuse intact? NO Inspect and test all relevant wiring for damage and short circuits. Repair as applicable. Renew the fuse. YES Is the wiring to the supply valve solenoid coil intact? Repair as applicable. NO YES Renew pilot supply valve solenoid valve stem. See Electrical Connections.

A402360 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section D Controls Section D 37 - 2 37 - 2 Precision Control (Servo)