Pilot Control Valves Removal and Replacement Note that the procedure shows the right hand control valve. The removal and replacement procedure for the left hand valve is identical. Before attempting to remove a pilot control valve the pilot circuit accumulator pressure must be vented. 1 Stop the engine. With the operator seat set in the rear facing position (for backhoe operation), switch the starter to ON without starting the engine. Operate the joystick controls several times to vent the servo pressure from the accumulator. Switch the starter switch to the OFF position. Removal 1 Reach inside the arm assembly and undo the two arm rest fixing bolts 1 .
Carefully lift the rear of the arm rest 2 and pull it to the rear to release. 2 Undo the retaining screws and remove the plastic covers 3 and 4 . Undo and remove bolt 5 together with lock washer 10 . Lift the link rod 6 to one side. 3 Note the phasing of the hoses connected at the valve 7 . If the hoses are not already tagged, tie on your own tags. Make sure you have recorded the connections correctly, enabling correct re-connection when replacing the valve. Disconnect the hoses at the valve. Cap all open hoses and ports. 4 Undo the three fixing bolts 8 and lift out the valve. Replacement Replacement is the reverse of removal. Make sure that the joystick gaiter 9 is correctly located.
9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section D Controls Section D 40 - 2 40 - 2 Precision Control (Servo)