www.WorkshopManuals.co.uk 74 - 1 Control Cables 74 - 1 Removal and Replacement Auxiliary Footpedal Cable The auxiliary footpedal control A is mounted in the cab floor as shown. The cable operates the auxiliary control valve located adjacent to the excavator valve. The cable is accessible underneath the rear L.H. corner of the cab. Note the routing of the existing cable and route the new cable in the same way. Removal 1 Park the machine on firm level ground, apply the parking brake. Lower the loader arms and excavator to the ground, switch OFF the engine and remove the starter key. 2 Working at the rear of the machine at the auxiliary valve, undo the locknut B .
Remove the screws C and slide back the housing D to reveal the clevis as shown. Remove the clevis pin E to release the cable. 3 At the footpedal remove the U-clamp F securing the cable to the bracket. Remove the spring clip G to release the cable. If the cable is to be replaced, remove and retain the microswitch operating tab H from the old cable as shown. A Replacement A394410 Replacement is the reverse of the removal sequence. C B D F G E H A404720 A404710 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section D Controls Section D