JCB — Loader Valve - Variable Flow

9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 2* Hydraulics Section E 2 - 7 2 - 7 Technical Data Relief Valve Pressures Loader Valve - Variable Flow bar kgf/cm2 lbf/in2 Priority Relief Valve† 170 - 176 173 - 179 2450 - 2550 Auxiliary Relief Valves (A.R.V.) @ 0.5gal/min (1.9 litres/min) Shovel Ram Head Side 170 - 174 173 - 177 2465 - 2520 Shovel Ram Rod side 306 - 314 312 - 320 4450 - 4550 † Note: Steer circuit pressure is controlled by a relief valve housed in the hydraulic steer unit (Refer to Section H Steering).

The priority relief valve housed in the loader valve must be set at 2500 lb/in2, this will ensure it does not interfere with the operation of the relief valve housed in the hydraulic steer unit. Weight: 2 Spool - TBA kg (TBA lbs) 3 Spool - TBA kg (TBA lbs) Component Key: 1 Auxiliary (optional) service 2 Shovel service 3 Arms lift service 4 Pump inlet 5 Tank port 6 Load sense port (to pump) 7 Priority load sense port (from steer unit) 8 Priority work port (to steer unit) 9 Load sense carry over port (to backhoe valve) 10 Service ports 11 Auxiliary relief valve (rod side) 12 Auxiliary relief valve (head side) 13 Priority relief valve † 3 2 1 ! 0 0 0 4 9 0 0 0 5 6 8 7 @ £ A273670 !

0 0 0 0 0 0 5